Identifying electrical faults in refrigeration systems requires comprehensive knowledge This knowledge includes the design and operation of the individual electrical components as well as the reading of circuit diagrams. Sci-tech Electrical Faults in Refrigerant Compressors Model RAC 084 helps to acquire this knowledge. The electrical components for the start and operation of a refrigerant compressor are clearly visibly arranged in a transparent showcase and already wired. The capacitor and start-up relay required for the motor are examined. Typical protection devices, such as circuit breaker and automatic fuse, are also arranged clearly visible.
Features
* Real refrigerant compressor from practice
* Investigation of important electrical components from refrigeration
* Simulation of 15 faults
Item Description
The simulation of 15 different faults, e.g. coil fracture in the motor, short circuit in the operating capacitor or welded contacts in the start-up relay, is possible. For fault indication, voltages and resistances are checked at the lab jacks with the multimeter. The depiction of the circuit diagram on the front panel facilitates the allocation of the measuring points. The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.
Technical Specifications
[1] Experimental unit from the Sci-tech practical series for the training of mechatronics engineers for refrigeration
[2] Investigation of the electrical components for the operation of a refrigerant compressor
[3] Real refrigerant compressor from practice
[4] Electrical components for the start and operation of the compressor arranged in the transparent switch cabinet
[5] General safety devices mounted clearly visible
[6] Circuit diagram depicted on the front panel
[7] Identification of 15 faults: multimeter measures voltages or resistances at the lab jacks
Technical Specifications
Refrigerant compressor
– power consumption: approx. 870W
Electrical components for the compressor
– start-up capacitor
– start-up relay
– operating capacitor
– overheat protection (bimetallic)
General safety devices
– main contactor
– automatic fuse