Air Duct Training System Model RAC 031
Home » Products » Air Duct Training System Model RAC 031
Air Duct Training System Model RAC 031
Air Ducts are used in many areas. They are used to ventilate offices, sports halls, production halls, conference halls etc. These systems consist of an air duct system and often other facilities for the conditioning of room air. There may also be elements for air purification or sound insulation, e.g. filters. Sci-tech Air Duct Training System Model RAC 031 examines how the air can be distributed in a building. The air duct system is supplied via a speed-controlled fan. The trainee constructs variable air duct systems from commercial components, such as pipes, bends, branches, filters and outlet valves. Connections for pressure measurements can be installed at any position.
Item Description
The effects of the individual components on the pressure loss and thus on the velocity and flow rate of the air are examined. For this purpose there are two manometers with different measuring ranges and a manual device for measuring the air velocity. The fan characteristic is also determined. To determine the power consumption of the fan there are a voltmeter and an ammeter. The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments
Technical Specifications
[1] Experimental set-up for training in ventilation engineering
[2] Radial fan, on mobile frame, to connect air ducts
[3] Air ducts from galvanized folded spiral-seam pipe with bends, joints and components
[4] Pressure measuring connections with variable locations
[5] Set of bends and connections, each DN 100 and DN 200: 90° bend, 45° bend, 45° branch, T piece, T piece with reducer, reducer, plug-in connection, pipe coupling
[6] Flow restriction elements, each DN 100 and DN 200: throttle valve, iris diaphragm
[7] Filters, each DN 100 and DN 200: pocket filter, filter cartridge
[8] 5 assembly stands to attach the air ducts
[9] Inclined tube manometer and digital manometer for 2 different measuring ranges
[10] Measuring of the air velocity by anemometer
[11] Switch cabinet with display of current and voltage
Fan
– power consumption: 1100W
– max. flow rate: 1680m³/h
– max. differential pressure: 1000Pa
– speed: 0…2800rpm
Pipes
– length: 1600mm
– diameter: 8x DN 200, 8x DN 100
Measuring ranges
– pressure: 0…200Pa / 0…2000Pa
– velocity: 0.25…30m/s
– current: 0…10A – voltage: 0…230V