Electrical Base Installation Trainer with Modules Model ELTR 015

Sci-tech Electrical Installations Trainers Base Unit & Modules ELTR 015 provides the technical institute students the knowledge of electrical circuitry for both residential and industrial wiring and circuits.

The various trainers are structured so that they can be tailor-made for different training levels by selecting the desired trainers as well as the electrical parts, components and connection accessories.

Main measuring, powering, indicators, readers, such as power supply, MCBs, Ammeters, Voltmeters, Watt-meters, etc are available on the base unit.

Special attention has been paid, while designing from the point of view of safety, protection, user friendliness, as well as regular up-gradation of the trainers for offering state-of-the-art technology.

Below given are different type of ‘Electrical Installation Trainers modules’ which can be procured separately to be used with base unit.

Modules:

  1. Electrical Safety & Protection Trainer Model ELTR 015A
  2. Electrical Industrial Installation Trainer Model ELTR 015B
  3. Electrical Industrial Installation Fault Simulator Trainer Model ELTR 015C
  4. Electrical Hospital Signaling Trainer Model ELTR 015D
  5. Electrical Residential Installations Trainer Model ELTR 015E
  6. Electrical Residential Electric Wiring Trainer Model ELTR 015F
  7. Anti-theft Electrical Trainer ELTR 015G
Size: 100cm x 40cm x 100cm (LxWxH)
Weight: 55 kg

Item Description

Sci-tech Electrical Installations Trainers Base Unit & Modules ELTR 015 provides the technical institute students the knowledge of electrical circuitry for both residential and industrial wiring and circuits.

The various trainers are structured so that they can be tailor-made for different training levels by selecting the desired trainers as well as the electrical parts, components and connection accessories.

Main measuring, powering, indicators, readers, such as power supply, MCBs, Ammeters, Voltmeters, Watt-meters, etc are available on the base unit.

Special attention has been paid, while designing from the point of view of safety, protection, user friendliness, as well as regular up-gradation of the trainers for offering state-of-the-art technology.  

Below given are different type of ‘Electrical Installation Trainers modules’ which can be procured separately to be used with base unit.

Modules:

  1. Electrical Safety & Protection Trainer Model ELTR 015A
  2. Electrical Industrial Installation Trainer Model ELTR 015B
  3. Electrical Industrial Installation Fault Simulator Trainer Model ELTR 015C
  4. Electrical Hospital Signaling Trainer Model ELTR 015D
  5. Electrical Residential Installations Trainer Model ELTR 015E
  6.    Electrical Residential Electric Wiring Trainer Model ELTR 015F
  7. Anti-theft Electrical Trainer ELTR 015G

Technical Specifications

Electrical Base Installation Trainer Model ELTR 015 consists of:

  • 3Ø AC Power Supply Panel
  • 4 pole MCB of 415 V/4A.
  • DOL 9A Contactor with 230V / 50 Hz / 11VA COIL.
  • Bimetallic thermal O/L relay with range 1.4A – 2.3A.
  • Pilot Lamp for Power Indicators of R-Y-B inputs
  • Manual Start / Stop switch with local trip contact

 

  • 3Ø AC Measurement Panel
  • Bidirectional Multifunction Meter to measure Power Line parameter.
  • 3 Phase ¾ wire, 415V, CT Input 5A
  • LCD/LED display, Aux supply 230V, 45-65 Hz, 5W
  • V, A, Hz, Pf, KVA, KW, KWH

 

  • Frequency Meter Panel  
  • 1Phase Frequency Meter
  • Range 45Hz-55Hz
  • Vibrating Pointer for Frequency Indication.

 

  • Power Factor Meter Panel
  • 1Phase Power Factor Meter
  • Range 0.5 Lagging- 0.5 Leading
  • Pointer for Power Factor Indication.

 

  • 3Ø AC Energy Meter Panel
  • 3 Phase, 4 Wire kWh Meter for Energy Consumption Measurement
  • ELCB / MCB & Fuse Panel
  • 1Phase / 2Pole ELCB/25A, 30mA Current imbalance (1 No)
  • 1Phase / 1Pole MCB/4A (4 No’s)
  • 10A Fuse (3 No)

 

  • ELCB & MCB Panel
  • 1Phase / 1Pole Phase MCB/6A (2 No’s)
  • 1Phase / 1Pole MCB/16A (2 No’s)
  • 3Phase / 3Pole MCB/16A (1 No)
  • 3Phase / 4Pole ELCB/63A (1 No)
  • AC Voltmeter Panel
  • AC voltmeter for three phase voltage measurement by selector switch
  • 1 Pole 4 way switch
  • Voltage Range: 500V
  • Selection of line voltage for three phase

 

  • AC Ammeter Panel
  • AC Voltmeter Range: 0-500V
  • AC Ammeter Range: 0-5A

 

Earth Leakage Relay Panel

  • Current Setting Range: 30mA-3.0 A (18 steps)
  • Tripping Time: 0.0 sec to 5.0 sec
  • 2 NO Trip contacts
  • Supply 85V to 275V AC/DC
  • 8A 250V AC/ 8A 30V DC 2C/O Contact Ratio
  • All connections of relay are brought out on this panel.

 

  • Lamp Load Panel                                                                           
  • Each panel consists of 230V/15/40/60/100W X 3 bulbs
  • Individual ON/OFF using 6A toggle switch
  • 21Ω/300W & 150Ω/300W Resistor for Earth Fault Simulation

 

Module: Electrical Safety & Protection Trainer Model ELTR 015A

The trainer enables learning and carrying out experiments on safety exposures of electrical systems, such as short circuit, current leakage, over-current, over-voltage, overload etc.

The training enables the students to understand how to deal with electrical safety system. The trainer allows students to operate different electrical devices that are commonly used in residential buildings, industries, hospitals, etc.

Safety sockets and switches located on the trainer panel allows separation of the circuit breakers from other devices and its connections to an external supply to study the operations.

Technical Specifications

Following devices are mounted on the trainer panel:

  1. Direct & indirect earthed connections
  2. Wiring Networks
  3. Transformer
  4. Power distribution board
  5. Fuses
  6. MCBs
  7. Motor CBs
  8. ELCBs
  9. Electrical motor diagram & connections
  10. Earthing Resistor
  11. Current Conductors
  12. Earthing Rod
  13. Indication lamp
  14. ON/OFF switches

Housed in aluminum board with line diagrams.

Experiment Capabilities

  • Short circuit
  • Current Leakage
  • Overload
  • Circuit breaker

 

Electrical Industrial Installation Trainer Model ELTR 015B

The trainer consists of a comprehensive set of integrated modules designed to be the building blocks of a large variety of industrial installations.

Each module contains one logic function, such as protection, push buttons, lamps, contactors, timer, and so on, and all of them can be easily connected to implement desired circuits. The connections are performed by means of safety connectors and cables used in power and low voltage control circuits.

The electrical components are mounted on the modules with their respective title and wiring details to show their internal electrical details.

Additional modular boards are available for addition of devices as per the syllabus.

 

Technical Specifications

Following devices are available on the trainer panel:

  1. Contactors with 24V Coil Voltage: 2NO+1NC contacts or 3NO+2NC contacts
  2. Double Contactor with 24V Coil Voltage & mechanical interlock: 2NO+1NC contacts or 3NO+2NC contacts
  3. Push Buttons: 1NO+1NC, in Red, Black or Green
  4. Rotation Reversing Switch: 20A AC, Forw-Off-Rev
  5. 4 – 2 Poles Commutator: Off – 1-2, 20A AC
  6. Pole Switching unit with inversion
  7. Pole Switching Unit with 2 separate windings
  8. Star-Delta switch: Off – S – D, 20A AC
  9. Star-Delta Starter with inversion
  10. Auxiliary Contactor with 24V Coil Voltage: 2NO+2NC Contacts, 4A
  11. Limit Switches
  12. Signaling Lamps
  13. Time Relay with 24V Coil Voltage: 1NO+1NC contacts, 0-30 sec, 4A
  14. Thermal Protection: 1NO+1NC contacts. Ratings 0.6-1A or 1-1.6A or 1.6-2.5A or 2.5-4A or 4-6.3A
  15. Three Phase Motor Protection Switch: Ratings 0.6-1A or 1-1.6A or 1.6-2.5A or 2.5-4A or 4-6.3A
  16. Position Sensor: Limit switch
  17. Inductive Proximity Sensor: Activation by magnetic field change
  18. Capacitive Proximity Sensor: Activation by capacitive change
  19. Level Magnetic Sensor: Liquid level sensors
  20. Photoelectrical Sensor: Activated by change in received light
  21. Photoelectrical Reflecting Sensor: Activated by change in reflected light

 

Electrical Industrial Installation Fault Simulator Trainer Model ELTR 015C

The Fault Simulator Trainer consists of 12 mini modules can be mounted to implement the control circuits described in the Manual. Large number of different circuits can be designed by the instructors and students using the modules.

The modules are aimed at implementation of industrial controls in order to create faults and simulate the fault conditions of more than 20 different types.

The Manual describes the faults that can be simulated in the circuits. Practically, this is how the Simulator can be used:

  • The instructor decides which circuit will be taken for experiment.
  • By referring to the Manual. The required Modules are mounted on the rack and connected.
  • The circuit is tested to make sure that there are no ‘real’ faults.
  • The instructor simulates the desired fault by operating the related switch on the back of the proper module.
  • The students analyze the failure and once found the cause, report their conclusion to the instructor.
  • If the students have correctly identified the cause, the instructor can reset the switch to prove the correctness of the analysis.

Technical Specifications

Following devices are available on the trainer panel:

  1. Contactors: 4 nos.
  2. Push Buttons: 1 no.
  3. Limit Switches: 1 no.
  4. Lamps: 2 nos.
  5. Timer: 2 nos.
  6. Magneto Thermal Switch: 2 nos.
  7. Rack Set

Options: Other configurations available as per syllabus.

 

Electrical Hospital Signaling Trainer Model ELTR 015D

Specially designed modules allow an assistance call to be sent by a patient to the nurse room. By pressing the call button on his panel, the patient activates the call and in the nurse room the request is posted on a panel by turning on the light corresponding to the calling room and sounding the common buzzer.

The nurse goes to the calling room and can turn the request off by pressing the Off button on the patient’s panel.

The modules need an external 24V Ac supply to activate the internal switches/relays/contactors.

 

Electrical Residential Installations Trainer Model ELTR 015E

Residential Wiring Installation modules set is practically an extension of industrial installation trainer, since it uses low rated similar devices.

The modules contain one logic function such as protection, switch, lap, relay, buzzer, electric lock, timer, etc that can be connected to assemble a desired circuit. The connections are performed by means of power and low voltage safety connectors and cables.

The electrical components are mounted on the modules with their respective title and wiring details to show their internal electrical details.

Additional modular boards are available for addition of devices as per the syllabus.

 

Technical Specifications

Following devices are available on the trainer panel:

  1. One Pole, One way Switch
  2. Dual Circuit Switch
  3. One Pole, two ways Switch
  4. One Pole Reversing Switch
  5. One Pole Push Button
  6. Illuminated Push Button
  7. Bell Pushbutton
  8. Bell-Door Opener Pushbutton
  9. Touch Sensitive Switch
  10. Maid – Valet Pushbutton
  11. ‘Break before make’ micro-switch: auxiliary contacts 1NO and 1NC
  12. ‘Make before break’ micro-switch: auxiliary contacts 1NO and 1NC
  13. Switch Relay
  14. Four Position Step Relay
  15. Light Dimmer with Switch
  16. Dusk-to-Dawn Switch
  17. Universal socket
  18. Lamp holder and Lamp
  19. Fluorescent lamp
  20. Emergency light
  21. Buzzer
  22. Bell
  23. Timing Relay
  24. Calling-Answering Unit
  25. House Phone
  26. Door Electric Lock

Additions for Bungalows/Residential Apartment Buildings

  • Fire Alarm Systems
  • Standby Battery
  • Smoke Detectors
  • Thermal Detectors
  • Acoustic & Light Indicators
  • Intruder Alarms

 

Electrical Residential Electric Wiring Trainer Model ELTR 015F

The module consists of a board of size 750mmX850mm on which the map of a typical apartment is drawn and each room contains the basic equipment required for distribution and utilization of electric power. Each electric component is accessed through 4mm safety connectors thus making it possible to implement a very large variety of residential installation circuits.

A typical apartment is considered that has 4 rooms and a balcony. The components are fixed on a board, connectable through safety connectors on the back side and identified by their titles on the front side. Input is 220V AC and so are the differential switch, LED lamps and the switch relay.

Living Room:

  • Main entrance is simulated through main control panel that contains the ine and the ground inputs, a 30mA differential switch, two fuses and a switch relay; the switch relay is bistable device that changes the status of its contact at each impulse received by its coil.
  • 3 lamps
  • 2 power sockets with ground connectors
  • 1 switch
  • 3 push buttons that are likely to be used to impulse the switch relay in order to control illumination from more than two points in the room

Kitchen:

  • 2 Lamps
  • 2 power sockets with ground
  • 2 switches

Bedroom:

2 lamps

2 exchange contact switches; may be used to control the lamps from both points

2 power sockets with ground

Bathroom:

  • 1 lamp
  • 1 power socket with ground
  • 1 common input and two output switches that may be used to control the lamp and the power socket

 

Balcony:

  • 1 lamp
  • 1 power socket with ground
  • 1 common input and two outputs switch that may be used to control lamp and power socket

 

Anti-theft Electrical Trainer Model ELTR 015G 

The module consists of a demonstration panel with slide-in modules on which the various functional modules are mounted required for anti-theft devices utilizing electric power/back-up battery systems. Each electric component is accessed through 4mm safety connectors thus making it possible to implement a very large variety of residential installation circuits.

A typical apartment can be considered experimental purpose based on the number of modules that are ordered. The components are fixed on a board, connectable through safety connectors on the back side and identified by their titles on the front side. Input is 220V AC and so are the differential switch, LED lamps and the switch relay.

 

Technical Specifications

Following devices are available on the trainer panel:

  1. One Pole, One way Switch
  2. Dual Circuit Switch
  3. Electrical Door Locks
  4. Remote control door Locks
  5. Electro-magnetic door locks
  6. Hidden video cameras
  7. Video recorders
  8. RIFD sensors for remote alarms
  9. Video House phones
  10. Video remote door openers/closers
  11. Window safety sensors
  12. Ultrasonic sensors
  13. IR Sensors
  14. Motion detectors
  15. Door Electric Lock
  16. Shock Sensors

Model Number