Boiler Drum Temperature Measurement BSG 003
Home » Products » Boiler Drum Temperature Measurement BSG 003
Boiler Drum Temperature Measurement BSG 003
Sci-tech Boiler Drum Simulation Trainer Model BSG 003 is able to perform Level Studies and Shell & Tube heat Exchanger Studies function. In Level Studies the level transmitter is capable of measuring drum level in open or close tank application using the differential pressure method or other suitable method
A heater is provided to heat up water in the drum and act as energy input to the boiler.
Level switch installed in the boiler drum to cut off the electric heater if drum level is low-pressure transmitter must be provided to measure the pressure.
In Shell and Tube heat Exchanger Studies consists of two main circuit: Hot water Circuit and Cold water Circuit
Size: | 70cm x 60cm x 95cm (LxWxH) |
Weight: | 65 kg |
Item Description
FEATURES
- Compact, comprehensive sturdy design
- Full instrumentation for experimentation on boiler control system.
- A pilot plant of boiler
- High – speed dynamic signal acquisition is possible.
- Menu driven screens with comprehensive HELP menu
- Displays graphically both on-line and historical trends
- PC based system.
- System having all process indication in color mimics.
- System is able to exhibit realistic response times, use standard industrial process instruments and process equipment
- System having facility of on line measurements for boiler drum level, feed water in flow, hot water outflow, drum pressure hot and cold water circuit temperature for heat exchanger and other instrumentations.
- Temperature, level and pressure indicator are provided for indication.
- Rota-meter is provided to measure flow rate.
- Air release valve is provided to release excess pressure to atmosphere, in case for over-pressure in the boiler drum for safety purpose
- Pressure and temperature gauges are provided.
- Provided with Alarm Annunciation
- Provided with Fault Stimulation Switches
- Powder coated structured is provided.
Sci-tech has designed the system in such a fashion that easily operated demonstrated & requisite experimentation can be performed. Sci-tech provides a comprehensive unit; The Sci-tech Boiler Drum Simulation Trainer Model BSG 003 is able to exhibit realistic response times, uses standard industrial process instruments and process equipment’s and designed to study the response of type ‘0’, ‘1’, and ‘2’ control system. It is a P.C. based system with visual display of the process on the monitor screen. The software used in this system is a windows-based software and is completely menu driven for experimentation. Visual display of MIMIC is provided with this system and graphics is viewed on monitor screen. Printing of data in tabular and graphical form is provided.
Sci-tech Boiler Drum Simulation Trainer Model BSG 003 is able to perform Level Studies and Shell & Tube heat Exchanger Studies function. In Level Studies the level transmitter is capable of measuring drum level in open or close tank application using the differential pressure method or other suitable method
A heater is provided to heat up water in the drum and act as energy input to the boiler.
Level switch installed in the boiler drum to cut off the electric heater if drum level is low-pressure transmitter must be provided to measure the pressure.
In Shell and Tube heat Exchanger Studies consists of two main circuit: Hot water Circuit and Cold water Circuit
See also different:
Sci-tech Electrical Voltage/Current/Energy/Wattage Measurement Trainer Model ELTR 012 is used for teaching students to measure ands calibrate electrical parameters in single phase and three phase electrical circuits.