Electrical Power Protection Relays Trainer Model ELTR 004 Series

Sci-tech Over – Under Voltage Protection Relays Trainer Model ELTR 004-01Sci-tech Directional Over Current Relay Trainer Model ELTR 004-02Sci-tech Percentage Based Differential Relay Trainer Model ELTR 004-03Sci-tech Power Factor Control Relay Trainer Model ELTR 004-04Sci-tech Under Over Frequency Relay Trainer Model ELTR 004-05

Sci-tech Over – Under Voltage Protection Relays Trainer Model ELTR 004-01

Sci-tech Directional Over Current Relay Trainer Model ELTR 004-02

Sci-tech Percentage Based Differential Relay Trainer Model ELTR 004-03

Sci-tech Power Factor Control Relay Trainer Model ELTR 004-04

Sci-tech Under Over Frequency Relay Trainer Model ELTR 004-05

Sci-tech Over - Under Voltage Protection Relays Trainer Model ELTR 004-01 has been designed particularly for average complexity educational training purpose for study of controlled protection relays for use in power distribution systems. High quality instrument, offers 5 push buttons and 8 digit display for 4 modes of operation in order to set and measure the parameters: .
  • MEASURE, to access one of four display areas
  • DISPLAY, to visualize the parameters
  • TEST, to test the unit
The unit is supplied with factory default parameter settings as listed in the manual. Sci-tech Over - Under Voltage Protection Relays Trainer Model ELTR 004-01 helps you to get fully acquainted with the basic concepts and functioning of Protection of relay in transmission line Trainer. Specification  Trainer consists of control panels mountable in 40X40mm Aluminum profile rack with sturdy table top flat panel.  4 no’s of ABS plastic panel mounted on the aluminum rack with mimic diagram  All input & output are terminated in 4mm shrouded connector, It is 4mm banana cable for experiments.  3phase DOL starter 4pole MCB, contractor & relay panel - 4 pole MCB of 415 V/4A . - DOL 9A Contactor with 230V / 50 Hz / 11VA COIL  3 phase multifunction meter panel - Bidirectional Multifunction - 3 Phase ¾ wire, 415V, CT Input 5A - LCD/LED display, Aux supply 230V, 45-65 Hz, 5W - V, A, Hz, Pf, KVA, KW, KWH - PC Communication: Modbus RTU RS485 (OPTIONAL)  Over current & elapsed Time measurement panel - Consists of AC ammeter of 20A - Elapsed time counter range 999.001 sec, resolution 1msec  Relay Panel - All connection of relay are brought out on this panel - 2 NO & 2 NC contacts - Relay Coil Connector  Table top 3 phase Dimmer. - 3 phase dimmer input 230V, 50Hz - Output 0-200V/ 3A  Table Top Protection Relay - Numerical/ Electromechanical type IDMT Over & Under Voltage type Accessories:  3 phase Variac 3 Amp.  Input Voltage 415V AC, 50 Hz. Output 470V AC/3A  Set of Manuals with Experiments.  Demo CD showing Experiments  Set of Shrouded Cables Optional Accessories:  Hand Held Tachometer….1 No  Working Table….1 No  Multimeter … 1 No  Tool Kit… 1 No Experiment Possibilities  To Plot characteristics of under voltage relay.  To Plot characteristics of over voltage relay.  Negative phase sequence protection   Sci-tech Directional Over Current Relay Trainer Model ELTR 004-02 helps you to get fully acquainted with the basic concepts and functioning of a Transmission Line Trainer. Specification  Trainer consists of control panels mountable in 40X40mm Aluminum profile rack with sturdy table top flat panel.  4 no’s of ABS plastic panel mounted on the aluminum rack with mimic diagram  All input & output are terminated in 4mm shrouded connector, its provide 4mm banana cable for experiments.  3phase DOL starter 4pole MCB, contractor & relay panel - 4 pole MCB of 415 V/4A . - DOL 9A Contactor with 230V / 50 Hz / 11VA COIL .  3 phase multifunction meter panel - Bidirectional Multifunction - 3 Phase ¾ wire, 415V, CT Input 5A - LCD/LED display, Aux supply 230V, 45-65 Hz, 5W - V, A, Hz, Pf, KVA, KW, KWH - PC Communication: Modbus RTU RS485 (OPTIONAL)  Over current & elapsed Time measurement panel - Consists of AC ammeter of 20A - Elapsed time counter range 999.001 sec, resolution 1msec  Relay Panel - All connection of relay are brought out on this panel - 2 NO & 2 NC contacts - Current rating 5A - Relay Coil Connector  Table top 3 phase Dimmer. - 3 phase dimmer input 230V, 50Hz - Output 0-200V/ 3A  Table Top Protection Relay - Directional, IDMT, Definite Time Over current static Relay  Table Top Resistive Load Panel - 3 nos of 600W resistors with switch selectable for 100, 112, 125, 150, 175, 200 & 225 Ohm. Accessories:  Set of Shrouded Cables  Set of Manuals with Experiments.  Demo CD showing Experiments Optional Accessories:  Hand Held Tachometer….1 No  Working Table….1 No  Multimeter … 1 No  Tool Kit… 1 No Experiment Possibilities  To plot Inverse Definite Minimum Time characteristics of over current relay.  To perform experiment on definite / instantaneous mode setting of the relay.  To perform experiment on Earth Fault mode setting of the relay.   Sci-tech Percentage Biased Differential Relay Trainer Model ELTR 004-03 helps you to get fully acquainted with the basic concepts and functioning of a Transmission Line Trainer. Specifications
  • Trainer consists of control panels mountable in 40X40mm Aluminum profile rack with sturdy tabletop flat panel.
  • 8 nos of ABS plastic panel mounted on the aluminum rack with mimic diagram
  • All input & output are terminated in 4mm shrouded connector, 4mm banana cable for experiments.
  • 3phase DOL starter 4pole MCB, contractor & relay panel
- 4 pole MCB of 415 V/4A. - DOL 9A Contactor with 230V / 50 Hz / 11VA COIL. - Bimetallic thermal O/L relay with range 1.4A - 2.3A
  • 3 phase multifunction meter panel (2nos)
- Bidirectional Multifunction - 3 Phase ¾ wire, 415V, CT Input 5A - LCD/LED display, Aux supply 230V, 45- 65 Hz, 5W - V, A, Hz, Pf, KVA, KW, KWH - PC Communication: Modbus RTU RS485 (OPTIONAL)
  • 1 phase Supply, Voltmeter & Ammeter Panel.
- 1 ph. MCBs of 4A. - 1 no. 0-300V Voltmeter & 0-2A Ammeter.
  • 1 phase Dimmer Panel.
- 1 phase dimmer input 230V, 50Hz - Output 0-200V/ 2 - Transformer with primary 230VAC/1A, secondary 0-2-8V/12A.
  • Over current & elapsed Time measurement panel
- Consists of AC ammeter of 20A - Elapsed time counter range 999.001 sec, resolution 1msec
  • Differential Relay Panel
- All connection of relay are brought out on this panel - 2 NO Trip contacts - Aux. Supply 110VDC/230VAC - Electromechanical / Numerical type-High speed biased differential relay. - Current rating 1A, with biased setting of 15%, 30% and 45% by patch connectivity, - Aux. supply 110VDC
  • CT panel (EMT48)
- Consist of 5/5 Amp. CT - Primary side of CTs are brought on 3 x 2 x 2 SBS sockets. - Secondary side of CTs are Star connected in group of 3 & brought out on 4 x 2 S B S sockets
  • Tabletop Star Delta Transformer Panel
- 1KVA 3 phase 415/230VAC Transformer - Star/Delta transformer connection facility
  • Tabletop Resistive Load panel.
- AC/DC Resistors 750E/ 600E/300E/ 212E / 162E/ 125E/112E/100E/400W
  • Tabletop Resistive Load panel.
- 3 nos of 600W resistors with switch selectable for 100, 112, 125, 150, 175, 2 0 0 & 225 Ohm. Accessories:  Set of Shrouded Cables  Set of Manuals with Experiments.  Demo CD showing Experiments.  Optional Accessories:  Handheld Tachometer….1 No  Working Table….1 No  Multimeter … 1 No  Tool Kit… 1 No Experiment Possibilities - To plot characteristics of % biased differential relay. - Pick up test for differential relay. - Transformer out zone or non-trip faults. - Transformer protection for in zone trips faults.   Sci-tech Power Factor Control Relay Trainer Model ELTR 004-04 helps you to get fully acquainted with the basic concepts and functioning of Power Factor Relays in power transmission and distribution. Specifications
  • Trainer consists of control panels mountable in 40X40mm Aluminum profile rack with sturdy tabletop flat panel.
  • 8 nos of ABS plastic control panels are mounted on the aluminum rack with mimic diagram
  • All input & output are terminated in 4mm shrouded connector, 4mm banana cable for experiments.
  • 3phase DOL starter 4pole MCB, contractor & relay panel
- 4 pole MCB of 415 V/4A. - DOL 9A Contactor with 230V / 50 Hz / 11VA COIL - Bimetallic thermal O/L relay with range 1.4A - 2.3A - Display: Indicators for R-Y-B Input
  • 3 phase multifunction meter panel (2nos)
- Bidirectional Multifunction - 3 Phase ¾ wire, 415V, CT Input 5A - LCD/LED display, Aux supply 230V, 45- 65 Hz, 5W - V, A, Hz, Pf, KVA, KW, KWH - PC Communication: Modbus RTU RS485 (OPTIONAL)
  • Contactor Panel
  • Rating: 9A, 230V / 50 Hz / 11VA COIL
  • Contacts: Power Contacts 3 NO type; Logic Contact 2 NO, 2 NC
  • Lamp Load Panel
  • Lamp Load: 15W / 40W / 60W / 100W / 200W, 230V AC with indicators (3 No’s)
  • Toggle Switch: ON/OFF for each bulb (3 No’s)
  • Relay Panel
  • Connector Relay Coil
  • Connection: All connection of relay are brought out on this panel
  • Resistive Load Panel
  • Resistive Loads: 100E / 125E / 150E / 175E / 200E / 225E / OFF 600W / 7 steps (3Nos) + 262E SIL tap.
  • Inductive Load Panel
  • Inductive Loads: 0.3H / 0.6H / 0.75H / 0.9H/1.2H/1.5H1A (3Nos)
  • VAR Compensation Panel
  • Capacitive Loads: 1 μF / 2 μF / 4 μF / 5 μF/ 6 μF / 8 μF / 10 μF & 15μF; 415V (3Nos)
  • Protection Relay Panel
  • Voltage Rating: Built in PT, can be connected between remaining two phases
  • Supply: 85-275V AC/DC
  • Contacts: 2 NO & 2 NC
  • Current Rating: 1A/5A
Accessories:  Set of Shrouded Cables  Set of Manuals with Experiments.  Demo CD showing Experiments. Optional Accessories:  Handheld Tachometer….1 No  Working Table….1 No  Multimeter … 1 No  Tool Kit… 1 No Experiment Possibilities
  • To control load power factor as per settings
  Sci-tech Under Over Frequency Relay Trainer Model ELTR 004-05 helps you to get fully acquainted with the basic concepts and functioning of a Transmission Line Trainer. Specification  Trainer consists of control panels mountable in 40X40mm Aluminum profile rack with sturdy tabletop flat panel.  8 nos of ABS plastic control panels are mounted on the aluminum rack with mimic diagram  All input & output are terminated in 4mm shrouded connector, its provide 4mm banana cable for experiments.  3phase DOL starter 4pole MCB, contractor & relay panel - 4 pole MCB of 415 V/4A . - DOL 9A Contactor with 230V / 50 Hz / 11VA COIL  3 phase multifunction meter panel. - Bidirectional Multifunction - 3 Phase ¾ wire, 415V, CT Input 5A - LCD/LED display, Aux supply 230V, 45-65 Hz, 5W - V, A, Hz, Pf, KVA, KW, KWH - PC Communication: Modbus RTU RS485 (OPTIONAL)  Over current & elapsed Time measurement panel - Consists of AC ammeter of 20A - Elapsed time counter range 999.001 sec, resolution 1msec  Relay Panel - All connection of relays are brought out on this panel - 2 NO & 2 NC contacts - Current rating 5A - Relay Coil Connector  Tabletop Protection Relay - Directional, IDMT, Definite Time Over current static Relay  Tabletop Single Phase AC Generator (Optional). - DC Shunt Motor Coupled 300VA, 1 phase AC Alternator - AC Output 0-220V, 40-65 Hz Output - SCR Drive Control panel for DC motor Accessories:  Set of Shrouded Cables  Set of Manuals with Experiments.  Demo CD showing Experiments. Optional Accessories:  Handheld Tachometer….1 No  Working Table….1 No  Multimeter … 1 No  Tool Kit… 1 No Experiment Possibilities   To Plot characteristics of Under Frequency relay.  To Plot characteristics of Over Frequency relay.